Close

Please select your country or region to be
directed to the appropriate Lesker site.

Sputter Process Diagnostics Form


This form is to help diagnose why the sputtering process is not depositing films with desired properties. Recommendations on ways to improve the sputtering process are supplied throughout this form.
To ensure effective assistance, please enter as much information as possible.

Note: measurement units must be selected by using the dropdown.

Problem Information

System Information

(See photo upload section for an example of where to find your system serial number)

    Reccomended:
  • <1.0 E-6 Torr
  • <1.3 E-6 mBar
  • <1.3 E-4 Pa

Pump to the recommended pressures above, verifying no leaks and purge to remove contaminates

Recommended to have SS gas lines from gas cylinder to sputter system

Recommended ~15 psi (~100 kPa)


%


(Decreasing throw distance is the best way to increase deposition rate)
Substrate Information



(Pre-clean substrate to improve adhesion and remove contaminates)
Target Information



Recommended max power density for a bonded target is 20 Watts per square inch (or 3 Watts per square centimeter)

Deposition Information



(Suggested when doing reactive nitride depositions)

If yes:



sccm


(Always light with pure argon and introduce reactive gas after pressure reduction)

(Must have flow setpoint > 10% of the max flow rate of the MFC for accuracy and stability)

If yes:



sccm


(Use same ramp rate down from deposition power)

(Reccomend 0.3 W/s for RF and 5 W/s for DC sputtering)

(Reccomend to pre-sputter until voltage stabilizes)

(If using a new compound target, an extended initial burn-in
is necessary to stabilize surface chemistry)

DC or Pulsed DC sputtering parameters:


(A steady decrease in voltage indicates the target not overheating. Repeatable voltage from run to run at the same deposition power and pressure indicates process stability)

If no,

RF sputtering parameters:




If no,

Photo Upload:
Please take the following photographs of the system:
  1. Inside of the process chamber
  2. Picture of sputter source (with shutter open and no components removed)
  3. Picture of sputter plasma
  4. Picture of the system description tag found on the rear of the electrical rack
    (Please see photo for example)

Please attach the photos of the system here:

File Attachments:
max size per file: 10mb
Other Comments:


Acknowledgment:

I Acknowledge


Contact Information:

* = Required

CAPTCHA
four + one equal
Type Your Answer Here
*



Click Here To Select Files
You may also drag and drop files into this box.
Accepted file types: .jpg, .png, .gif, .pdf, .docx
Max 4 files. 10mb per file.
Preparing files for upload...
Contact Us - Sputter Process Diagnostics Form