Specifications
Mass Range | 1.00 - 100 amu |
---|---|
Sensitivity |
3.000 x 10-4
A/Torr |
Pressure |
Minimum Detectable Partial, Electron Multipler 2.000 x 10-14 mbar 1.500 x 10-14 Torr Minimum Detectable Partial, Faraday Cup 3.500 x 10-12 mbar 2.600 x 10-12 Torr Operating 5.000 x 10-4 mbar 5.000 x 10-4 Torr |
Temperature |
Bakeout (without Electronics) 300 ºC 572 ºF Maximum Operating, Electron Multiplier 150 ºC 302 ºF Maximum Operating, Faraday Cup 200 ºC 392 ºF |
Sensor Mounting Flange |
DN35CF-DN40CF (2.75 in / 69.85 mm OD)
|
Filament Protection |
Built-in pressure plate to automatically turn off emission upon reaching pressure threshold
|
Resolution - Peak Width (amu) at 10% of peak height |
0.9
|
Zero Blast Interference at Mass 2 |
<100
|
Standard Communication |
Ethernet connection; IP address with static or automatic assignment
|
Software |
Built-in web interface for monitoring, control, and data acquisition; no downloadable software required |
Additional Command Interface |
Demo LavVIEW drivers and full access to API for end user built command protocol
|
Electrical Connector for I/O & Relays |
Standard 15 pin sub D
|
Power Input |
20-30 VDC
24 VDC typical |
Power Connection |
Latching, 4 pin DIN connector, internally isolated from system ground |
Sensor Length (Vacuum Side) in (mm) |
5.63 ( 143 ) |
Electronics Dimensions (L x W X H) in (mm) |
6.69 x 4.53 x 4.79 (170 x 115 x 121 ) |
Weight lbs (kg) |
6.00 ( 2.72 ) |
Source Type |
Open Ion Source
|
Detector Type |
Faraday Cup/Electon Multiplier
|
Filament Options |
Yttria-Coated Iridium
|
Firmware Updates
Update Type |
Downloadables | Files | Release Date |
Replaces Version |
Download |
---|---|---|---|---|---|
Python Script | Word document and python | How to use the python script and new python script. | 6/15/2022 | N/A |
Accessories for the KJLC Element
Note: Below you will find common accessories for an RGA that will help maintain the life of the unit. If you do not see an accessory that you need, please contact your local KJLC Sales Representative.
Product | Description | Suggested Part Number | Components Needed |
---|---|---|---|
Isolation Valve (Suggested) | An isolation valve allows the KJLC Element RGA to be isolated while not in use to reduce contamination and/or allows for the KJLC Element RGA to be removed from the chamber without having to vent to atmosphere. A 2.75" CF isolation valve is suggested. |
Manual Valves: SA0150MCCF
Pneumatic Valves: SA0150PCCF, SE024D4XX |
KJLC Angle Valve, Mounting hardware, and solenoid (only for pneumatic valve). |
Heater Jacket Kits (Suggested) | A heater jacket kit provides a method to uniformly bake-out the KJLC Element RGA to reduce or remove contamination. The KJLC Element RGA can be baked out to 300°C while the electronics removed, 200°C while the Faraday Cup only is in operation, or 150°C while the Electron Multiplier is in operation. You still need to keep the electronics at or below 50°C however. |
961-029-G1 (US 120V) 961-029-G2 (DE 240V) 961-029-G3 (UK 240V) |
All heater jackets kits include Heater Jacket, Power Cord, Mounting Kits, and Cable set. |
Extension Tube (Included) | An extension tube allows the RGA sensor to be mounted outside of the chamber to reduce line of sight and possible contamination. An 8" extension tube is suggested. |
Custom Nipple Builder
FN-C3113080 |
Extension tube included with KJLC Element RGA. |
Communication Cable (Included) | Ethernet cable needed to connect the RGA to a laptop for communication. | — | 10ft. cable included with KJLC Element RGA. 7m and 15 m cables available in accessories table. |
Connecting Hardware (Included) | Hardware used to connect the KJLC Element RGA to the chamber. | — | DN40CF gasket, nuts, and bolts are included with the KJLC Element RGA. |
Power Supply (Required) | Standard power supply to power the RGA. |
ELE163600 (US Power Supply) ELE163601 (EU Power Supply) ELE163602 (UK Power Supply) |
Region specific power supply kit includes power supply and appropriate cable. |